The gauge features: withstanding pulsation of medium and loading's striking, and resistance to environmental vibrations, suitable for measuring pressure of gases liquids none corrosive copper and the alloy of copper and steam. It equipped with a maximum and minimum connection switch mechanism, so that when the pressure reaches a predetermination value, the instrument would emit a signal or severe the electrical connection, used for automation and signally purpose. The shockproof structure effectively controls the needles shaking rushing and protects the connection points. So to allow the instrument to display clearly, send reliable signals and function stably. It's widely suitable for mechanical, chemical, petrol, extraction mining, electric power industrial production processes.
Specification:
| Model |
YTXC-100ZQ-Z |
YTXC-150ZQ-Z |
YTXC-100-Z |
YTXC-150-Z |
YTXC-100TQ-Z |
YTXC-150TQ-Z |
| Structure Style |
fore part, axial |
?No edge, radial |
fore part, radial |
Scale range
MPa |
-0.1-0.15;-0.1-0.3;-0.1-0.5;-0.1-0.9;-0.1-1.5;-0.1-2.4
0-0.25; 0-0.4; 0-0.6; 0-1.0; 0-1.6; 0-2.5; 0-4.0; 0-6.0; 0-10; 0-16; 0-25; 0-40; 0-60 |
Accuracy
% |
± 1.6 |
| Contact's electric specification |
Operational voltage |
380VAC;220VDC |
| Maximum operational current |
1A |
| Continuous current |
0.6A |
| Maximum power( no inductance load ) |
20VA |
| Adjoin instrument |
X14K4P |
Junction box |
X14K4P |
Junction box |
X14K4P |
Operational temperature: -25℃~55℃
Operational maximum pressure: does not exceed 2/3 of the gauge's maximum.
Operational environment must have vibration frequency less than 25Hz and amplitude less than 0.5mm.
Design: Q/320211 DGH05-2004
Dimension:
 |